  rs-485 port protection evaluation board 2 11/11 ? fu1107 rs-485 evaluation board 2 bill of materials table 1 no. part number qty. description reference 1 tbu-ca065-300-wh 2 tbu? single bidirectional line 650 v 300 ma tbu? hsp 1, tbu? hsp 2 2 MOV-10D201K 2 single line 10 mm mov 200 v mov1, mov2 3 cdsot23-sm712 2 dual bidirectional line 7 v / 12 v tvs5 introduction tis evaluation board serves as an aid in evaluating circuit protection on rs-485 serial device port solutions using bourns? tbu? high-speed protector (hsp), mov and tvs products to meet the required industry standards on rs-485 port interfaces. te recommended bourns? tbu? hsp solution ofers enhanced performance features over competing technologies, which can help the design engineer to increase the surge & transient protection level on rs-485 ports and place the entire circuit protection solution into a smaller pcb area. bourns has developed a rs-485 evaluation board (measuring 50 mm x 25 mm x 1.2 mm) manufactured using fr4 pcb with nickel gold plating on top and bottom sides. how to connect the evaluation board for test set-up ? connect j1 and j2 to the exposed lines. ? connect j3 and j4 to the rs-485 ic device. * in addition to the two tbu? hsps, the default confguration of this board uses two movs (mov1, mov2) and a single tvs diode array (tvs5). te board allows diferent confgurations: ? 2 movs (mov1 and mov2) may be replaced by a) 2 single 2031 gdts (gdt1 and gdt2) or b) a dual 2030 gdt (gdt3, not yet released) ? 1 tvs diode array (tvs3) may be replaced with a) 2 smb tvs diodes (tvs1, tvs2) or b) 2 sot23 tvs diodes (tvs3, tvs4) or c) 2 sot23-5 thyristor devices (tisp1, tisp2) rs-485 evaluation board 2 top side layout* rs-485 evaluation board 2 schematic figure 2 figure 1 tbu? hsp 1 t vs5 tisp1 tisp2 t vs1 t vs2 t vs3 t vs4 gd t3 gd t1 mov1 line a unprotec ted 40 mils trac ep rote ct ed load a line b unprotec ted 40 mils trac ep rote ct ed load b j1 j 2 j3 j4 gd t2 mov2 tbu? hsp 2 3 2 1 3 2 1 3 3 2 1 12 21 21 21 2 1 1 1 2 2 1 2 1 2 ii i i i ii ii i ii nu nu 1 2 12
rs-485 port protection evaluation board 2 performance graphs 11/11 ? fu1107 esd +8 kv contact discharge (iec-61000-4-2) surge 1.2/50 5 kv 120 v rms 28 v rms figure 3 figure 4 figure 5 figure 6 ch 1: input voltage / surge / fault to tbu? hsp ch 4: tbu? hsp current 1 ch1 ch1 116 v ma 400 ns 31.60 % 1.00 a ch4 200 v ch1 ma x 329 v ch1 mi n -20.5 v tr ig? pr ev u ch4 ma x 1.98 a ch4 mi n -81.1 ma t t 4 the ohm unit following the current units shown for channel 4 (i. e. ao hm) indic ates that a 50 ohm termination w as used internal to the oscilloscope t ch 1: input voltage / surge / fault to tbu? hsp ch 4: tbu? hsp current 1 ch1 line 116 v ma 4.00 ms 20.20 % 200 ma ch4 100 v ch1 ma x 124.4 v run tr ig d ch4 ma x 365.4 ma ch4 mi n -322.4 ma t t 4 the ohm unit following the current units shown for channel 4 (i. e. ao hm) indic ates that a 50 ohm termination w as used internal to the oscilloscope t ch 1: input voltage / surge / fault to tbu? hsp ch 4: tbu? hsp current 4 1 ch1 line 116 v ma 4.00 ms 20.20 % 200 ma ch4 20.0 v ch1 ma x 28.3 v run tr ig d ch4 ma x 451.8 ma ch4 mi n -395.7 ma t t the ohm unit following the current units shown for channel 4 (i. e. ao hm) indic ates that a 50 ohm termination w as used internal to the oscilloscope t reference or more information on implementin advanced circuit protection technoloies for rs- ports please review the bourns rs- application note httpwww.bourns.comdatalobalpdfsbournsrs-ppnote.pdf tbu is a registered trademark of bourns, inc. in the u.s., taiwan and european community. bourns is a registered trademark of bourns, inc. in the u.s. and other countries. copyright? 2011 ? bourns, inc. ? 11/11 ? e/fu1107 www.bourns.com ch 1: input voltage / surge / fault to tbu? hsp ch 4: tbu? hsp current 1 ch1 ch1 -380 v ma 10.0 ns 20.40 % 5.00 a ch4 500 v ch1 ma x 545 v ch1 mi n -390 v tr ig? run ch4 ma x 11.3 ma ch4 mi n -2.55 a t t 4 the ohm unit following the current units shown for channel 4 (i. e. ao hm) indic ates that a 50 ohm termination w as used internal to the oscilloscope t


▲Up To Search▲   

 
Price & Availability of MOV-10D201K

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X